Addressable emergency lighting
A system where each emergency fitting reports its status to a central panel, so faults show up without walking the building.
Batten
A long, surface-mounted linear fitting, traditionally holding fluorescent tubes; LED battens replace them as complete luminaires.
BS 5266-1
The UK code of practice for emergency lighting of premises. The current edition is BS 5266-1:2025.
BS 7671
The IET Wiring Regulations. The current version is BS 7671:2018+A4:2026, still the 18th Edition.
BS EN 1838
The standard for emergency lighting light levels. BS EN 1838:2024 sets at least 1 lux across the width of an escape route.
BS EN 12464-1
The standard for lighting indoor workplaces, which sets maintained illuminance, glare and uniformity targets for tasks such as office work (500 lux).
BS EN 50172
The standard for installing, verifying, operating and testing emergency lighting, including monthly and annual tests.
Circuit-watt
The total power drawn by a lighting circuit, including drivers and control gear, used when measuring efficacy for Building Regulations.
Colour rendering (CRI or Ra)
How faithfully a light source shows colours compared with a reference. Higher values suit retail, healthcare and workshops.
Colour temperature
How warm or cool white light looks, measured in kelvin (K). Around 3000 K looks warm; 4000 K is neutral and common in offices.
DALI
Digital Addressable Lighting Interface, a control standard that lets each fitting be dimmed, grouped and monitored individually.
Daylight harvesting
Automatically dimming electric lighting when there is enough daylight, using a daylight sensor.
Driver
The electronic unit that powers an LED fitting, the LED equivalent of a fluorescent ballast.
Efficacy
Light output per watt of power, in lumens per watt. Building Regulations set minimum efficacy for new lighting.
Electrical Installation Certificate (EIC)
The certificate issued under BS 7671 for new installations or circuits.
EICR
Electrical Installation Condition Report, a periodic inspection of an existing installation.
Escape route lighting
Emergency lighting that lets people find and use escape routes safely when the normal supply fails.
High bay
A fitting designed for tall spaces, usually above about six metres, such as warehouses and factories.
High-risk task area lighting
Emergency lighting that lets people make a dangerous process safe before they leave.
IK rating
A rating for a fitting's resistance to impact, important in sports halls and vulnerable areas.
IP rating
Ingress Protection rating, showing resistance to dust and water. External and kitchen fittings need suitable IP ratings.
LENI
Lighting Energy Numeric Indicator, an alternative way of showing lighting energy compliance based on annual energy use per square metre.
Lumen
A measure of the total light given out by a source.
Lux
A measure of light falling on a surface: one lumen per square metre. Light meters read in lux.
Maintained emergency lighting
Emergency fittings that stay lit all the time and continue when the supply fails, typical for exit signs.
Maintained illuminance
The light level a design must not fall below over its life, allowing for dirt and ageing.
MEWP
Mobile elevating work platform, such as a scissor or boom lift, used for high-level work.
Non-maintained emergency lighting
Emergency fittings that only light when the normal supply fails.
Open area (anti-panic) lighting
Emergency lighting that lets people move safely from large open spaces to an escape route.
Part-night dimming
Reducing external lighting to a lower level during the quietest hours of the night.
Photocell
A sensor that switches lighting on at dusk and off at dawn.
PIR sensor
Passive infrared sensor that detects movement and switches lights on or keeps them on.
Rated duration
How long emergency lighting must run on battery, set by design and risk assessment; three hours is common.
Self-test emergency lighting
Fittings that run their own functional and duration tests and show a status indicator.
UGR
Unified Glare Rating, a measure of discomfort glare from a lighting installation. Lower is better for offices.
WEEE
Waste electrical and electronic equipment. Old fittings and fluorescent tubes must be disposed of through proper routes.