Emergency lighting testing in Four Throws
Monthly function tests, annual duration tests and certificates. If fittings in your Four Throws premises fail their annual test, we give you a fixed price for replacement batteries or fittings before we leave.

Local emergency lighting testing in Four Throws
Annual emergency lighting tests in Four Throws are best booked for late afternoon or evening, so batteries can recharge overnight before people are back in.
Where Four Throws buildings have changed layout, the annual test is a good moment to check that routes are still properly covered.
Our teams travel to Four Throws from across Kent. Typical nearby jobs include Cranbrook, Salehurst and Burwash, so we can often combine survey visits.
Four Throws at a glance
What's included
- Annual full-duration discharge tests
- Log book completion and certificates
- Fault reports with fixed prices for repairs
- Battery and lamp replacements
Guide prices in Four Throws
Typical budgets for Four Throws premises, supplied and installed, excluding VAT.
| Item | Guide budget (ex VAT) | Basis |
|---|---|---|
| Monthly emergency lighting function test | £55 – £160 | per visit |
| Annual 3-hour emergency lighting test | £135 – £430 | per visit, small system |
| Emergency luminaire or exit sign | £65 – £160 | per fitting, supplied and fitted |
| Commercial electrician | £320 – £535 | per day |
Example: annual 3-hour test of a small system, about £135 – £430 excluding VAT. Fixed price after a free survey.
Rules that apply in Four Throws
For buildings in Four Throws, the duty to provide adequate emergency lighting where escape routes need it, and to keep it tested, sits with the responsible person under the Regulatory Reform (Fire Safety) Order 2005.
Four Throws FAQs
Is the price fixed?
Yes. After the survey you get a fixed price for the scope agreed. If you add to the scope later, we price the extra before doing it.
Do you cover all of Four Throws?
Yes. We work across Four Throws and the TN18 and TN17 postcode districts, plus nearby places such as Cranbrook, Salehurst and Burwash.
Which rules apply to lighting work in Four Throws?
Fire safety duties come from the Regulatory Reform (Fire Safety) Order 2005. For new lighting, Approved Document L sets the energy efficiency requirements. We design and certify work to BS 7671 and, for emergency lighting, BS 5266-1.
How often should emergency lighting be tested?
A brief functional test monthly and a full rated-duration test once a year, with results recorded. BS EN 50172:2024 also calls for illuminance measurement at five-year intervals.