Fit-out and new-build lighting in Dumfries and Galloway
Fit-out lighting is the installation of new lighting, controls and emergency lighting during a commercial fit-out, refurbishment or new-build, from first-fix containment and cabling to second-fix luminaires and commissioning. We cover Dumfries and Galloway, including Dumfries, Annan and Castle Douglas.

Fit-out and new-build lighting work in Dumfries and Galloway
We coordinate with ceiling and partition trades on Dumfries and Galloway fit-outs so first fix is done before ceilings close.
Fit-outs in Dumfries and Galloway need lighting that meets current energy rules on the day building control signs off, so we check efficacy at design stage.
What's included
- First-fix containment and cabling, second-fix luminaires
- Coordination with ceiling, partition and M&E trades
- Part L (or national equivalent) efficacy evidence for building control
- Controls designed in, not bolted on
Guide prices in Dumfries and Galloway
Typical budgets for Dumfries and Galloway, supplied and installed, excluding VAT. Your fixed price follows a free survey.
| Item | Guide budget (ex VAT) | Basis |
|---|---|---|
| LED panel (600×600) | £50 – £150 | per fitting, supplied and fitted |
| LED batten (complete luminaire) | £80 – £200 | per fitting, supplied and fitted |
| Emergency luminaire or exit sign | £60 – £150 | per fitting, supplied and fitted |
| DALI dimming and control | £50 – £150 | per luminaire, on top of the fitting |
Example: 80 LED fittings and 20 emergency fittings in a new office fit-out, about £5,200 – £15,000 excluding VAT.
Rules that apply in Dumfries and Galloway
Fire safety duties for premises in Dumfries and Galloway come from the Fire (Scotland) Act 2005 and the Fire Safety (Scotland) Regulations 2006. Whoever is responsible for fire safety must make sure escape routes are lit if the normal supply fails, and that the system is tested and maintained.
Standard 6.5 of the Scottish building standards covers efficient, controllable lighting. The non-domestic guidance uses 95 luminaire lumens per circuit-watt for general lighting, or LENI.
Towns we cover in Dumfries and Galloway
Fit-out and new-build lighting FAQs for Dumfries and Galloway
Which fire safety law applies in Dumfries and Galloway?
The Fire (Scotland) Act 2005 and the Fire Safety (Scotland) Regulations 2006 sets the duties of the person responsible for fire safety, including emergency lighting where escape routes need it.
Which towns in Dumfries and Galloway do you cover?
All of Dumfries and Galloway, including Dumfries, Annan and Castle Douglas. See the towns list on this page for local pages.
Do you work as a subcontractor?
Yes. We can work for a main contractor or directly for the occupier.