Office lighting is the design and installation of luminaires that light desks, meeting rooms, circulation areas and receptions to the right level without glare. We cover Cornwall, including Redruth, Falmouth and St Austell.

Office lighting work in Cornwall
For office lighting in Cornwall we design to about 500 lux on desks, as BS EN 12464-1 suggests, and keep glare off screens by choosing the right optics rather than simply adding more light.
Offices in Cornwall range from older suspended-ceiling floors with 600×600 fluorescent panels to newer exposed-soffit spaces where suspended linear LED looks and works better.
What's included
- Layouts that hit around 500 lux on desks with low glare on screens
- Emergency lighting checked and integrated with the new layout
- Presence detection in meeting rooms, toilets and stores
- LED panels, linear suspended fittings or downlights to suit your ceilings
Guide prices in Cornwall
Typical budgets for Cornwall, supplied and installed, excluding VAT. Your fixed price follows a free survey.
| Item | Guide budget (ex VAT) | Basis |
|---|---|---|
| LED panel (600×600) | £50 – £155 | per fitting, supplied and fitted |
| Presence (PIR) sensor | £40 – £80 | per sensor, installed |
| Daylight sensor | £60 – £120 | per sensor, installed |
| DALI dimming and control | £50 – £155 | per luminaire, on top of the fitting |
Example: 60 LED panels with presence sensing in a 600 m² open-plan office, about £3,650 – £10,400 excluding VAT.
Rules that apply in Cornwall
Approved Document L (2021 edition, with 2023 amendments) asks for new general lighting to average at least 95 luminaire lumens per circuit-watt, or to use the LENI method. The 2026 edition raises this to more than 105 for work under it from 24 March 2027.
In Great Britain, common T8 fluorescent tubes were caught by ecodesign rules from 1 September 2023 and the mercury exemptions for ordinary T5 and T8 lamps ended on 1 February 2024.
Office lighting by town in Cornwall
- Office lighting in Redruth
- Office lighting in Falmouth
- Office lighting in St Austell
- Office lighting in Truro
- Office lighting in Camborne
- Office lighting in Newquay
- Office lighting in Penzance
- Office lighting in Bodmin
- Office lighting in Saltash
- Office lighting in Antony
- Office lighting in Bude
- Office lighting in Callington
- Office lighting in Calstock
- Office lighting in Camelford
- Office lighting in Colan
- Office lighting in Forrabury and Minster
- Office lighting in Fowey
- Office lighting in Hayle
- Office lighting in Helland
- Office lighting in Helston
- Office lighting in Kenwyn
- Office lighting in Liskeard
- Office lighting in Looe
- Office lighting in Lostwithiel
- Office lighting in Marazion
- Office lighting in Padstow
- Office lighting in Penryn
- Office lighting in Perranarworthal
- Office lighting in Perranporth
- Office lighting in Rame
- Office lighting in Sancreed
- Office lighting in South Petherwin
- Office lighting in St Agnes
- Office lighting in St Blaise
- Office lighting in St Breock
- Office lighting in St Columb Major
- Office lighting in St Endellion
- Office lighting in St Ives
- Office lighting in St Keverne
- Office lighting in St Mewan
- Office lighting in St Teath
- Office lighting in Tintagel
- Office lighting in Tregoney
Office lighting FAQs for Cornwall
How are prices set in Cornwall?
Our guide prices are adjusted for regional labour costs. After a survey you get a fixed price for the agreed scope.
Which fire safety law applies in Cornwall?
The Regulatory Reform (Fire Safety) Order 2005 sets the duties of the person responsible for fire safety, including emergency lighting where escape routes need it.
How many lux does an office need?
BS EN 12464-1:2021 gives 500 lux maintained on the task area for writing, reading and data processing. Surrounding areas, corridors and break-out spaces can be lower. The standard also sets limits for glare and uniformity.
Can you work outside office hours?