For office lighting in Dundee and Angus we design to about 500 lux on desks, as BS EN 12464-1 suggests, and keep glare off screens by choosing the right optics rather than simply adding more light.

We usually phase office work in Dundee and Angus over evenings, one zone at a time, so nobody loses a desk while the ceiling is opened up.

What's included

  • Emergency lighting checked and integrated with the new layout
  • Layouts that hit around 500 lux on desks with low glare on screens
  • LED panels, linear suspended fittings or downlights to suit your ceilings
  • Presence detection in meeting rooms, toilets and stores

Guide prices in Dundee and Angus

Typical budgets for Dundee and Angus, supplied and installed, excluding VAT. Your fixed price follows a free survey.

Guide prices in Dundee and Angus
ItemGuide budget (ex VAT)Basis
LED panel (600×600)£50 – £150per fitting, supplied and fitted
Presence (PIR) sensor£40 – £80per sensor, installed
Daylight sensor£60 – £120per sensor, installed
DALI dimming and control£50 – £150per luminaire, on top of the fitting

Example: 60 LED panels with presence sensing in a 600 m² open-plan office, about £3,600 – £10,200 excluding VAT.

Rules that apply in Dundee and Angus

Standard 6.5 of the Scottish building standards covers efficient, controllable lighting. The non-domestic guidance uses 95 luminaire lumens per circuit-watt for general lighting, or LENI.

In Great Britain, including Scotland, common T8 fluorescent tubes were caught by ecodesign rules from 1 September 2023 and the mercury exemptions for ordinary T5 and T8 lamps ended on 1 February 2024.

Scotland does not use the England and Wales EPC E letting rule. Instead, some non-domestic buildings over 1,000 m² need an action plan when sold or let, under Section 63 regulations.

Office lighting by town in Dundee and Angus

Office lighting FAQs for Dundee and Angus

Which towns in Dundee and Angus do you cover?

All of Dundee and Angus, including Dundee, Arbroath and Brechin. See the towns list on this page for local pages.

Which fire safety law applies in Dundee and Angus?

The Fire (Scotland) Act 2005 and the Fire Safety (Scotland) Regulations 2006 sets the duties of the person responsible for fire safety, including emergency lighting where escape routes need it.

Do we need sensors in an office?

They are worth it in meeting rooms, toilets, kitchens and stores, where lights are often left on. Daylight dimming along windows also saves energy in perimeter zones.

Panels or linear pendants?

Recessed 600×600 panels suit suspended grid ceilings and are the simplest swap. Linear suspended fittings suit exposed soffits and can light both the desk and the ceiling, which makes a space feel brighter.

Related services in Dundee and Angus

Office lighting in nearby areas

Get a fixed-price lighting quote

Free survey, clear scope, certified work. Prices exclude VAT.