COMMERCIALLighting.uk

Warehouse lighting in Leyland

From offices to warehouses, we handle warehouse lighting for Leyland businesses. Every job starts with a survey and ends with testing, certification and a clear fitting schedule.

Warehouse lighting in Leyland

LED high bays and aisle lighting for warehouses and distribution sites. We plan lift access in Leyland around your picking routes and loading times, so the warehouse keeps moving while the work is done.

Large warehouse with rows of LED high bay lights above pallet racking

Local warehouse lighting in Leyland

In Leyland distribution units the key is the optic. Narrow-beam fittings down each aisle put light on the rack faces where pickers need it, rather than on the top of the racking.

Aisle-by-aisle presence sensing works well in Leyland warehouses where some aisles are only visited a few times an hour.

Leyland sits within Lancashire. We work throughout the PR25, PR26 and PR5 postcode districts and surrounding places, including Bamber Bridge, Chorley and Preston.

Leyland at a glance

AreaLancashire
Postcode districtsPR25, PR26, PR5, PR6
NearbyBamber Bridge, Chorley and Preston
RulesThe Fire Safety Order; Approved Document L

What's included

  • Lux checks after installation against the agreed design
  • LED high bays or narrow-beam aisle fittings matched to racking heights
  • Presence sensing per aisle so empty aisles dim or switch off
  • Loading bay, dock leveller and yard lighting

Guide prices in Leyland

Typical budgets for Leyland premises, supplied and installed, excluding VAT.

Guide prices in Leyland
ItemGuide budget (ex VAT)Basis
LED high bay£145 – £390per fitting, supplied and fitted
LED batten (complete luminaire)£80 – £195per fitting, supplied and fitted
Presence (PIR) sensor£40 – £80per sensor, installed
Scissor or boom lift hire£145 – £295per day

Example: 60 LED high bays in a 3,000 m² warehouse, with 3 days of lift hire, about £9,250 – £24,400 excluding VAT. Fixed price after a free survey.

Rules that apply in Leyland

Approved Document L (2021 edition, with 2023 amendments) asks for new general lighting to average at least 95 luminaire lumens per circuit-watt, or to use the LENI method. The 2026 edition raises this to more than 105 for work under it from 24 March 2027.

In Great Britain, common T8 fluorescent tubes were caught by ecodesign rules from 1 September 2023 and the mercury exemptions for ordinary T5 and T8 lamps ended on 1 February 2024.

Leyland FAQs

Which rules apply to lighting work in Leyland?

Fire safety duties come from the Regulatory Reform (Fire Safety) Order 2005. For new lighting, Approved Document L sets the energy efficiency requirements. We design and certify work to BS 7671 and, for emergency lighting, BS 5266-1.

Do you remove the old fittings in Leyland?

Yes. Old fittings are removed, and fluorescent tubes are recycled as hazardous waste through an authorised route, with paperwork for your records.

Can you work out of hours in Leyland?

Yes. Evening, weekend and phased working is common for Leyland offices, shops and warehouses, so the business keeps running.

What lux level does a warehouse need?

It depends on the task. BS EN 12464-1:2021 examples include 100 lux for stores and stockrooms, 150 lux at the floor of rack storage, 200 lux for open storage and loading, and 300 lux for packing and grouping.