Office lighting in Aust

If your premises in Aust need office lighting, we can usually survey within days. Work is carried out by vetted electricians working under S&K and certified on completion.

Office lighting in Aust

Glare-free LED lighting for desks, meeting rooms and receptions. Available across Aust and Gloucestershire. Many Aust office landlords upgrade lighting between tenancies, because LED with presence sensing helps the EPC and leaves the next occupier with lower running costs.

Modern office meeting area lit by suspended linear LED fittings

Local office lighting in Aust

If your Aust office has window bays, daylight sensors can dim the perimeter row of fittings on bright days without anyone noticing.

We usually phase office work in Aust over evenings, one zone at a time, so nobody loses a desk while the ceiling is opened up.

Our teams travel to Aust from across Gloucestershire. Typical nearby jobs include Bradley Stoke, Frampton Cotterell and Yate, so we can often combine survey visits.

Aust at a glance

AreaGloucestershire
Postcode districtsBS35, BS32
NearbyBradley Stoke, Frampton Cotterell and Yate
RulesThe Fire Safety Order; Approved Document L

What's included

  • LED panels, linear suspended fittings or downlights to suit your ceilings
  • Layouts that hit around 500 lux on desks with low glare on screens
  • Daylight dimming along window bays
  • Out-of-hours installation so desks stay usable during the working day

Guide prices in Aust

Typical budgets for Aust premises, supplied and installed, excluding VAT.

Guide prices in Aust
ItemGuide budget (ex VAT)Basis
LED panel (600×600)£50 – £155per fitting, supplied and fitted
Presence (PIR) sensor£40 – £80per sensor, installed
Daylight sensor£60 – £120per sensor, installed
DALI dimming and control£50 – £155per luminaire, on top of the fitting

Example: 60 LED panels with presence sensing in a 600 m² open-plan office, about £3,650 – £10,400 excluding VAT. Fixed price after a free survey.

Rules that apply in Aust

Approved Document L (2021 edition, with 2023 amendments) asks for new general lighting to average at least 95 luminaire lumens per circuit-watt, or to use the LENI method. The 2026 edition raises this to more than 105 for work under it from 24 March 2027.

In Great Britain, common T8 fluorescent tubes were caught by ecodesign rules from 1 September 2023 and the mercury exemptions for ordinary T5 and T8 lamps ended on 1 February 2024.

Privately rented commercial property in England generally needs an EPC of E or better, or a registered exemption, and lighting is one of the cheaper ways to improve a rating.

Aust FAQs

How quickly can you survey in Aust?

Most surveys in Aust can be booked within a few working days. Tell us about any deadlines, such as a lease end or a fire risk assessment action, and we will try to fit around them.

Which rules apply to lighting work in Aust?

Fire safety duties come from the Regulatory Reform (Fire Safety) Order 2005. For new lighting, Approved Document L sets the energy efficiency requirements. We design and certify work to BS 7671 and, for emergency lighting, BS 5266-1.

Who does the work in Aust?

Work is carried out by vetted electricians working under S&K Property Investments and Improvement Ltd, which is responsible for the job and invoices you directly.

Do we need sensors in an office?